First, view the FAQ before asking about your LA6 Signal Tower.
Questions
about your operations concerns
Q1What
is the signal line input status when attempting data transfer?
It does not operate untill after transfer completion.
Q2What
is the "Signal Input" method?
A one-shot trigger input is used for the "Smart Mode" "Pulse Trigger Type"
input.
All other inputs use a level hold input.
Q3Can
the main unit combine the "Single Display", "Time Trigger", and "Pulse
Trigger" in the "Smart Mode"?
No, they cannot be combined in the "Smart Mode."
Only one of the three "Single Display", "Time Trigger" or "Pulse Trigger" can be
used at a time.
Q4Is
it possible to toggle between the "Signal Tower" mode and "Smart
Mode"?
It is possible to toggle between the two modes. If the mode switch is
turned "ON", it will operate in the "Smart Mode."
If the mode switch is turned "OFF", it will operate in "Signal Tower Mode."
Q5If
the LA6 is turned on after the information set transfer of LA6 goes wrong,
will all the LA6 tiers flash in red?
When power is applied to the LA6, the normal information setting is
automatically checked.
If the information set contents is inaccurate, all tiers will flash in red.
If this occurs, retransmit the information set with the LA6 application
software.
Q6During
the "Smart Mode" time trigger operation, why does the display color change
earlier than the set-up time?
The default setup for the LA6 application software time span is set as 0.1
seconds. If a "5" is entered for the lighting time, the lighting pattern will
be held for 0.5 seconds. It is recommended to set the time span for one
second, so the unit can operate for a one second duration.
Q7While
in the "Smart Mode" time trigger operation, why doesn't it progress to the
next lighting pattern when lighting pattern 1 is held to be
displayed?
If "0 seconds" is entered in the LA6 application software during the lighting
time, the setup becomes infinite and does not progress to the following lighting
pattern. If nothing is set up, then "0 seconds" is entered as a default
value.
Questions
about your wiring concerns
Q8Can
two or more units be synchronized to operate simultaneously?
No, they cannot be synchronized.
Even when starting two or more units simultaneously, a lag will occur with the
flashing or alarm sound.
Q9Can
the flashing and pulse enable common line be used in the "Smart
Mode"?
It cannot be used in the "Smart Mode." It may cause intermittent or adverse
operation.
Q10What
cable is necessary to connect with the main unit from the personal computer
so that data can be created from the LA6 application software?
A micro-USB cable for Charging/Data Transfer (USB A male to USB Micro-B male) is
necessary.
Q11Can
a USB connection turn the product on just by plugging the USB into the
product?
No, it cannot be powered by the USB connection.
Q12Is
it necessary to supply power to the LA6 main unit to transfer data from the
LA6 application software to the LA6?
It is possible to transfer data, even if there is no power supplied to the
LA6.
However, the simulation function cannot be used while there is no power supplied
to the LA6.
Q13What
precautions should be made for unused signal wires?
Every unused signal wire should be insulated with insulation tape, etc.
If it is bundled without insulation, wires may short-circuit and cause unwanted
or intermittent operation.
Questions
about your software concerns
Q14After
changing the setup data, is turning the power "ON" and "OFF"
necessary?
Turning the power "ON" and "OFF" is not necessary.
Q15What
is the setting range for the "Time Trigger Type" lighting?
For each pattern: 0.1 second - 360 seconds (time-span setup: 0.1 second); 1
second - 3600 seconds (time-span setup: 1 second).
Q16Is
it possible to read what the registered information is set to in the main
unit?
It is possible to transmit if the data creation was made with the LA6
application software.
As a caution, keep in mind that the current information set will be overwritten.
Q17Why
doesn't the pattern change in the "Time Trigger Type" mode?
When the set up value for the lighting time is "0", the time becomes infinite
and pattern changes do not occur.
Q18Can
a display color be selected from 21 colors when a sign pattern and Flash
Reduction setup is used?
Yes, but it is limited to 9 colors.
Q19Can
a dimming setup be used for every group?
It is possible for every group.
Q20Can
the alarm sounds be previewed in the LA6 application software?
No, they cannot be heard from the LA6 application software. It is possible
to hear sample sounds by going to our company website and listening to the sample sounds.
Q21What
OS supports the data creation for the LA6 application software?
Windows 7 (32/64 bit versions)
Windows 8 (32 bit / 64 bit version)
Windows 8.1 (32 bit/ 64 bit version)
Windows 10 (32 bit/ 64 bit version)
* Although it has been checked for Windows XP, since Microsoft Co. no longer
supports the OS, no warranty or guarantee exists.
Q22What
is the difference between the information set (.dat) and pattern data
(.dts)?
The information set contains data for the "Signal Tower" mode and various "Smart
Mode" applications.
Pattern data is group data used for the "One-time Trigger" or "Pulse Trigger"
input functions.
Q23How
is the pattern data added to the data creation for the LA6 application
software?
The LA6 application software has an import function that can be used to add the
pattern data.
Refer to the help section in the LA6 application software for details.
Q24What
is the creation method for making pattern data?
The LA6 application software has an export function that can be used to create
the pattern data.
Refer to the help section in the LA6 application software for details.
Q25Why
is there an error message with the LA6 application software during the
transfer of the information set to the LA6?
For slower computers, or sluggish transfer rates, there is a function to change
the data transfer rate for the LA6 application software version 1.03 and
above. If the LA6 application software version being used is already 1.03 or
above, try to change the transfer rate from a high speed to the standard speed
and transfer again.
Q26Why
is the LA6 application software help file display strange?
Or it's not even showing?
The personal computer's security administration may be restricting functions
from the LA6 application software, or it may be the network connection is
restricting it from being viewed.
Q27What
can be done about the LA6 application software not starting up, or when it
becomes locked-up?
It may have become corrupted during decompression. Depending on the personal
computer's directory structure archiver at the time of setup, it may had
decompressed in the same folder, without making a new folder. If it does not
make a new folder and all files are extracted in the same hierarchy while being
decompressed, an error will occur. Try resetting the archiver set-up so it
will maintain the proper directory structure, and try to decompress again.